Fire Alarm & Fighting

Please Register/Login to see the price.

HP101U-16

• The HP101U Series ConventionalFire Alarm Control Panel is a 24 volt, four to sixteen-zone,Class B,Conventional Fire Alarm ControlPanel. De· signed exclusively to meet the latest market requirements and future ULC

pdf_iconHST Fire Alarm System

Add to cart

HB101-16

  • Microprocessor based conventional flre alarm Repeater panel
  • 16 Detection Zones Repeater Panel
  • Relay output for fire Condition
  • Zones Fault LEOs Indication
  • Zones Fire LEOs Indication
  • RS485 Port for panel Connection up to 1.2Kmeter distance
  • Up to 8 repeater Can be connected to one panel
  • sounder Outputs
  • 24 Voltage needed from panel
  • 4 wire connection to main panel2 for power ,2 for RS485
  • This repeater can be connected to any HST Type from 4 Zones to 16

 

pdf_iconHST Fire Alarm System

Add to cart

HB101-12

12 Detection Zones Panel

  • 32 Detector per Zone
  • 2 Relay output for fire Condition
  • Zones Fault LEOs Indication
  • Zones Isolation LEOs indication
  • Fault Relay Output
  • Auxiliary Output for 28Voltage
  • RS48S Port for repeater up to 1.2Kmeter distance
  • Up to 8 repeater Can be connected to one panel
  • 2 sounder Outputs
  • Switched mode power supply 24V,3A with 2 battery charger 12v
  • End Of Line Statues Detection
  • Short circuti /open circuit detection
  • Open collector fault output
  • 28 V SOmA fused supply output on Fire
  • Switched mode power supply 3A output

pdf_iconHST Fire Alarm System

Add to cart

HP101U-8

The HP101U Series ConventionalFire Alarm Control Panel Is a 24 volt, four to sixteen-zone, Class B,Conventional Fire Alarm ControlPanel. De­ signed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective IDC1000 Series can be used in a variety of low- to mid-sized applications.

Add to cart

HB101-8

  • Microprocessor based conventional fire alarm controlpanel
  • One man test
  • 12 Detection Zones Panel
  • 32 Detector per Zone
  • 2 Relay output for fire Condition
  • Zones Fault LEOs Indication
  • Zones Isolation LEOs indication
  • Fault Relay Output
  • Auxiliary Output for 28Voltage
  • RS48S Port for repeater up to 1.2Kmeter distance
  • Up to 8 repeater Can be connected to one panel
  • 2 sounder Outputs
  • Switched mode power supply 24V,3A with 2 battery charger 12v
  • End Of Line Statues Detection
  • Short circuti /open circuit detection
  • Open collector fault output
  • 28 V SOmA fused supply output on Fire
  • Switched mode power supply 3A output

pdf_iconHST Fire Alarm System

Add to cart

HP101U-4

The HP101U Series ConventionalFire Alarm Control Panel is a 24 volt,

four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective IDC1000 Series can be used in a variety of low- to mid-sized applications.

pdf_iconHST Fire Alarm System

Add to cart

HB101-4

  • Up to 8 repeater Can be connected to one panel
  • 2 sounder Outputs
  • Switched mode power supply 24V,3A with 2 battery charger 12v
  • End Of Une Statues Detection
  • Short circuit /open circuit detection
  • Open collector fault output
  • 28 V SOmA fused supply output on Fire
  • Switched mode power supply 3A output

pdf_iconHST Fire Alarm System

Add to cart

HP103 REPEATER

  • Panel Hstfire+1 8 Hstfire+9-16.
  • Mains Voltage 01AC) 240 240.
  • System Vohage (V DC) 28.4 28.4 jUUiescent l:urrent, uns11enced.
  • Fault (mA).
  • Minimum Battery Size 2 x 12V 7 7.
  • Required (Ah).
  • Delector Voltage 01DC) 20 20.
  • Number of Sense Zones 1-8 9-16.
  • Maximum Number of Detectors 30 30.
  • Firing Resistance (Ohms) 510 ±200 510 ±200.
  • Sense Zone End of Une (Ohms) 31<3 3k3 o\larmVoltaqe (VDC) 28.4 28.4.
  • Number of .Alarm Zones 2 2.
  • Maximum.Alarm Current per Zone 300 300.
  • Maximum Number of Sounder 16 16 o\larm Zone End of Lone (Ohms) 10k 10k.
  • Max. AUXIliary :>upp1y o.;urrem sot sot.

pdf_iconHST Fire Alarm System.

Add to cart