Fire Alarm & Fighting

Please Register/Login to see the price.

HD203

Maximum Alarm
Current (LED on) 7 mA@24 \IOC
Operating Humidity
Range 10% to 93%Relative Humidity, Non-condensing
Operating Temperature
Range 14•F to 122•F (•1o•c to5o•C)
Fixed Temperature
Rating
135°F (57°C)
Rate of Rise Detection Responds to greater than 15.F/min
Height 2.2′” (55 mnn)installed inBase
Diameter 4.0″ (1Cl3 mm)
jWeight 5.5 oz.(1$ g)

pdf_iconHST Fire Alarm System

Add to cart

HD203-MINI

5 mA @ 24 VDC
Operating Humidity
Range 10% to 93% Relative Humidity, Non-condensing
Operating Temperature
Range
14°F to 122°F (-10°C to50°C)
Smoke Sensitivity 0.15-0.30dB/m
Fixed Temperature
Rating
135°F (57°C)
Rate of Rise Detection Responds to greater than 15°F/min
Height 42 mm installed in Base
Diameter 64 mm

pdf_iconHST Fire Alarm System

Add to cart

HD201

The detector is plug-in type photoelectronic smoKe and heat sensors with addres sable

analog communications. The sensors transmit an analog representation of smaKe density or ternperature over a communication line to a

control panel. 1nside Mcu’s EEPR OM Keep the

sensor’s address that can be set by a portable

Address setting device.Two LEOs on the sensor are controlled by the panel to indicate sensor status.

 

pdf_iconHST Fire Alarm System

Add to cart

HD202

Operating Voltage
Range 15 to 28 VDC
Standby Current 400A @ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 7 mA@24 VDC
Operating Humid y
Range 10% to 93% Relative Humidity,
Non-condensing
Operating Temperature
Range 14•F to 122•F (-1o•c to5o•C)
Fixed Temperature
Rating 135°F (57°C)
Rate of Rise Detect1on Responds to greater than 15•F/min
Height 2.2′” (55 mm) installed inBase
Dai meter 4,0′” (103 mm)
ight 5.5 oz .(155 g)

pdf_iconHST Fire Alarm System

Add to cart

HD202-MINI

Operating Voltage
Range 15 to28 VDC
Standby Current 650A@ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 5 mA@24 VDC
Operating Humidity
Range 14•F to 122•F (-1o•c toso•C)
Operating Temperature
Range 10% to 93%Relative Humidity,
Non-condensing
Smoke Sensitivity 0.15-0.30d8/m
Height 42 mm instalied in Base
Diameter 64mm

pdf_iconHST Fire Alarm System

Add to cart

HS203

Operating
Temperature
– 10°C to 50°C
Operating Humidity 0 to 95 RH,
Operating Voltage 22VDC to 30VDC
Average Current 70 mA
Light Output ≥ 1.2 WS
Flash Rate ≤ 2 seconds
Sound Level ≥ 100dB
Light Life ≥ 30000 flashes

pdf_iconHST Fire Alarm System

Add to cart

HD201-MINI

Operating Voltage
Range 15 to28 VDC
Standby Current 650A@ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 5 mA@24 VDC
Operating Humidity
Range 14•F to 122•F (-1o•c toso•C)
Operating Temperature
Range 10% to 93%Relative Humidity,
Non-condensing
Smoke Sensitivity 0.15-0.30d8/m
Height 42 mm instalied in Base
Diameter 64mm

pdf_iconHST Fire Alarm System

Add to cart