SM-AC680
1 ×
×User name : | |
Email : | |
Password : | |
Confirm Password : | |
Already Registered ! Click Here to login. |
User name : | |
Password : |
Description & Features
• ModelHM201•SC Is a negative-switching• Loop Isolator, which is fully
compatible with HST Intelligent addressable protocol.
• The module incorporates an amber LED to show when it is isolating a
section of the loop, and when used under each addressable Sensor if a single short circuit was to occur on the loop then no Sensors would be lost.
• The HM201-SC does not use an address, and has the same wiring configuration as the HD200 Base making It very simple to install.
• Detects short circuits on loop
• Status LED
• Connection of up to 159 per loop
• Allows connection of Sensors from the HST Range
• Bayonet slot, low Insertion force for detectors
• Quick connection via square cable clamps
HP203C Local LCD
Addressable Fire Alarm Control Panel
Repeaters
HP201C View for all events
Designed and manufactured to the highest standards in a quality controlled environment the HP203C fire alarm annunciator provides a simple and convenient method of extending the controls and indications of
the HP201C fire alarm control panel to other locations. The large, graphic liquid crystal display and high brightness LED indicators duplicate the indications on the HP201C Addressable fire alarm control panel at up to 4 additional locations via a simple, two-wire serial data connection. The HP203C is available in a 24V
DC powered (which can be powered via an additional
• The HP101U Series ConventionalFire Alarm Control Panel is a 24 volt, four to sixteen-zone,Class B,Conventional Fire Alarm ControlPanel. De· signed exclusively to meet the latest market requirements and future ULC
12 Detection Zones Panel
The HP101U Series ConventionalFire Alarm Control Panel Is a 24 volt, four to sixteen-zone, Class B,Conventional Fire Alarm ControlPanel. De signed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective IDC1000 Series can be used in a variety of low- to mid-sized applications.
The HP101U Series ConventionalFire Alarm Control Panel is a 24 volt,
four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective IDC1000 Series can be used in a variety of low- to mid-sized applications.
Conventional Ultra VIolate Flame Detector
bling the detector.
indication.
The gas Detector Is designed for single station use.Small and compact, small commercial properties, and recreational vehicles. It is intended to detect leakage of natural gas (methane gas), town gas, and bottled gas (propane gas).
5 mA @ 24 VDC
Operating Humidity
Range 10% to 93% Relative Humidity, Non-condensing
Operating Temperature
Range
14°F to 122°F (-10°C to50°C)
Smoke Sensitivity 0.15-0.30dB/m
Fixed Temperature
Rating
135°F (57°C)
Rate of Rise Detection Responds to greater than 15°F/min
Height 42 mm installed in Base
Diameter 64 mm
Maximum Alarm
Current (LED on) 7 mA@24 \IOC
Operating Humidity
Range 10% to 93%Relative Humidity, Non-condensing
Operating Temperature
Range 14•F to 122•F (•1o•c to5o•C)
Fixed Temperature
Rating
135°F (57°C)
Rate of Rise Detection Responds to greater than 15.F/min
Height 2.2′” (55 mnn)installed inBase
Diameter 4.0″ (1Cl3 mm)
jWeight 5.5 oz.(1$ g)
Description & Features
• This Conventional8’Bell very low power consumption
• Standard: 8 inch
• Rated Voltage:24V
• Rated current: 1OmA
• Sound:89dB/3m(A)
• Material: aluminium
• Temperature:1•0 to 60
• Humidity: s930
The detector is plug-in type photoelectronic smoKe and heat sensors with addres sable
analog communications. The sensors transmit an analog representation of smaKe density or ternperature over a communication line to a
control panel. 1nside Mcu’s EEPR OM Keep the
sensor’s address that can be set by a portable
Address setting device.Two LEOs on the sensor are controlled by the panel to indicate sensor status.
Operating Voltage
Range 15 to 28 VDC
Standby Current 400A @ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 7 mA@24 VDC
Operating Humid y
Range 10% to 93% Relative Humidity,
Non-condensing
Operating Temperature
Range 14•F to 122•F (-1o•c to5o•C)
Fixed Temperature
Rating 135°F (57°C)
Rate of Rise Detect1on Responds to greater than 15•F/min
Height 2.2′” (55 mm) installed inBase
Dai meter 4,0′” (103 mm)
ight 5.5 oz .(155 g)
Nominal Operating
Voltage 15 to 28 VDC
Standby Current ≤1mA @ 24 VDC
Maximum Alarm
Current (LED on) ≤5 mA @ 24 VDC
EOL resistance 4.7K Ohms
Operating Humidity
Range
10% to 93% Relative Humidity,
Non-condensing
Operating Temperature
Range -10°C to50°C
Dimension 120 mm L x 80mm W x 43mm H
Weight 175 g
Description & Features
• ModelHM201•Z is a single Circuit Zone Controller designed to allow up to 15 conventional detectors to be Interfaced to HST addressable system. Full monitoring against malfunction or disconnection,together with a self• test feature through the HST protocol,ensure the integrity of the HM201•Z at all times.
• Single Loop Address
• Powered loop
• Supports one Zone of ConventionalDetectors
• Up to 159 module per loop
• Up to 15 conventionaldetector can be connected to this module
INTELLIGENT ADDRESSABLE Sounder Module HM201-S
Description & features
• Single Loop Address
• Each Alarm Circuit Fused at 1 amp
• One Sounder Circuits
• Each Circuit Fully Monitored for Open and Short Circuit Faults
• Outputs can be Driven Continuously or Synchronized Pulsed Sounder
Drive
• Model HM201-S is an Intelligent sounder module which has been designed to provide one sounder outputs (that can be driven Bells or Siren) with full fault montioring. The monitored input can be used for local power supply fault monitoring or as a general-purpose input.
• The HM201-S utilises simple DIP switches for reliable addressing
Operating Voltage
Range 15 to28 VDC
Standby Current 650A@ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 5 mA@24 VDC
Operating Humidity
Range 14•F to 122•F (-1o•c toso•C)
Operating Temperature
Range 10% to 93%Relative Humidity,
Non-condensing
Smoke Sensitivity 0.15-0.30d8/m
Height 42 mm instalied in Base
Diameter 64mm
Operating
Temperature
– 10°C to 50°C
Operating Humidity 0 to 95 RH,
Operating Voltage 22VDC to 30VDC
Average Current 70 mA
Light Output ≥ 1.2 WS
Flash Rate ≤ 2 seconds
Sound Level ≥ 100dB
Light Life ≥ 30000 flashes
Operating Voltage
Range 15 to28 VDC
Standby Current 650A@ 24 VDC (one communication
every 5 seconds with LED blink enabled)
Maximum Alarm
Current (LED on) 5 mA@24 VDC
Operating Humidity
Range 14•F to 122•F (-1o•c toso•C)
Operating Temperature
Range 10% to 93%Relative Humidity,
Non-condensing
Smoke Sensitivity 0.15-0.30d8/m
Height 42 mm instalied in Base
Diameter 64mm
Description & Features
• This Conventional Siren very low power consumption
• Rated Voltage:24Volt
• Rated current:SOmA
• Sound:89dB/3m(A)
• Material: Fire Proof Plastic
• Temperature:-10 to 60
• Humidity:930
Description & Features
• Operating Temperature •1o•c to so•c
• Operating Humidity 0 to 95 RH,
• No condensation or Icing
• Operating Voltage 22VDC to 30VDC
• Average Current 70 mA
• Light Output 1.2 WS
• Flash Rate 2 seconds
• Sound Level 1OOdB
• Light Life 30000 flashes
Description & Features
bling the detector.
indication.
Conventional Photoelectric Smoke Sensor
Description & Features
Description & Features
• The HC102 is a Conventional call-point based upon our industry
standard series housing and features easy to install, push•fit wiring terminals.
• The unit can support either a ‘Frangible Glass’ element or a ‘Non
Frangible Plastic’ element.
• Push in and Pull Down Call point
• Can be reset by Key
• Red colour
• Fire proof materials
• 470 Ohm Resistance
• Modern style Call Point
Description & Features
• This Conventional6′ Bell very low power consumption
• Voice volume:96dB/(mA)
• Rated current: 10 to 18 mA
• Size: 6′ of DC 24V
• Diameter: 150mm
• Temperature:-10 – 50
• Humidity:at or below 93%